Steel Column Design using Eurocode 3

Steel column design for Eurocode 3, EN 1993-1-1, is discussed in this article. Each design and design process is discussed comprehensively.

Steel column is designed for axial compression and the bending stress induced by the connecting elements. Not like the concrete steel is weak in compression. Mainly, there are two types of failures in steel columns.

Crushing Materials

Reaching the material to its capacity and failing due to inadequate capacity to carry the applied load.

This kind of failure could be due to the inadequate compressive strength and or cross-sectional area.

Member Buckling

Overall bucking or local bucking could lead to steel column design failures. Local bucking is dependent on the sectional properties.

Overall buckling depends on several factors.

You may refer to the article on column failure methods for different types of concrete column failures.

Let’s discuss the desing aspect of the axial load Column.

Steel Column Design Procedure

Firstly it is required to classify the section according to the dimensions of the section and material properties.

Based on the slenderness limits, classification of section into categories, Class 1, Class 2, Class 3, and Class 4. Accordingly, Class 1,2 & 3 sections are classified into non-slender sections and Class 4 sections are classified as slender sections.

You may refer to Cl 5.5.2 of EN 1993-1-1 (EC3) for further information.

Consider H section, let see what are the limits available to classify the section. The limits are as follows as indicated in Table 5.2.

Ratio Class 01 Class 02 Class 03
Compression Flange of Rolled Section Cf/tf 10ε 14ε
Web of Rolled Section Cw/tw 33ε 38ε 42ε